Generic selectors
Exact matches only
Search in title
Search in content
Post Type Selectors
Search in posts
Search in pages
Filter by Categories
Case Report
Case Series
Editorial
Editorial Board
Guest editorial
Images
Letter to Editor
Original Article
Review Article
Generic selectors
Exact matches only
Search in title
Search in content
Post Type Selectors
Search in posts
Search in pages
Filter by Categories
Case Report
Case Series
Editorial
Editorial Board
Guest editorial
Images
Letter to Editor
Original Article
Review Article
Generic selectors
Exact matches only
Search in title
Search in content
Post Type Selectors
Search in posts
Search in pages
Filter by Categories
Case Report
Case Series
Editorial
Editorial Board
Guest editorial
Images
Letter to Editor
Original Article
Review Article
View/Download PDF
Original Article
3 (
2
); 112-116
doi:
10.25259/SAJHS_30_2026

Translate:

Haematology critical values: Cross-sectional analysis and insights

Author affiliations
Department of Pathology, Sri Devaraj Urs Medical College, Kolar, Karnataka, India
Department of Medicine, Sri Devaraj Urs Medical College, Kolar, Karnataka, India
Article History
Corresponding author(s)

*Corresponding author: Geetanjali Anilkumar Burbure, Assistant Professor, Department of Pathology, Sri Devaraj Urs Medical College, Kolar, Karnataka, India. geetaab12@gmail.com

Article tools · PDF & citations

Abstract

Objectives:

The laboratory critical value (CV) reporting has gained significance in recent times due to national and international focus on patient safety. International Organization for Standardization (ISO) 15189: 2012 has accepted CV notification (CVN) as an essential part of accreditation in medical laboratories. Hence, the present study was conducted to document the CVs and analyse clinician satisfaction of CVN.

Material and Methods:

This study was a cross-sectional, descriptive, observational and analytical study design for the period of one year (Jan 2024 to Dec 2024). The parameters considered critical are haemoglobin, platelet count and white blood cell count (WBC) as per the standard operating procedure (SOPs) followed in Sri Devaraj Urs medical college. A test result that was significantly outside the normal range and that required immediate communication was considered as a “CV”. CVs were communicated to the clinicians within 30 mins of reporting. All the CVs were documented. A survey was conducted to analyse the satisfaction of clinicians over haematology CVN.

Results:

Among 90,717 haematology samples analysed, 4,408 were classified as CV, representing 4.8%. The highest CVs were received from the medicine department, 2362 (53.5%), followed by the paediatric department, 750 (15.16%). The analytes most notified CV was haemoglobin, 2476 (2.73%) followed by platelets, 1727 (2.27%) and WBCs, 166 (0.22%).

Conclusion:

Most CVs were reported from the Department of Medicine, with adults forming the largest affected age group. Implementation of the CVN system facilitated timely communication of life-threatening laboratory results, enabling early clinical intervention and improving patient outcomes in critical care settings.

Keywords

  • Clinician satisfaction survey
  • Critical value analysis
  • Critical value notification
  • Critical values
  • Haematology section
Licence
This is an open-access article distributed under the terms of the Creative Commons Attribution-Non Commercial-Share Alike 4.0 License, which allows others to remix, transform, and build upon the work non-commercially, as long as the author is credited and the new creations are licensed under the identical terms.

How to cite this article: Burbure GA, Suresh TN, A R. Haematology critical values: Cross-sectional analysis and insights. South Asian J Health Sci. 2026;3:112-6. doi: 10.25259/SAJHS_30_2026

INTRODUCTION

Laboratory services are the hidden treasures of any hospital; they have the immense ability to transform patient care and improve patient safety practices. Critical value (CV) analysis is a crucial part of the post-analytical quality indicator. The timely communication and proper identification of CV is an essential part of good Laboratory practice. CV interpretation not only speaks about the laboratory performances but also has a huge effect on patient care, ultimately saving a life from a life-threatening condition.[1] CV notification (CVN) has become an essential part of accreditation procedures at the International Organisation for Standardisation (ISO) 15189: 2012.[1,2]

The Joint Commission (JC) defines a critical test as “A test result that is significantly outside the normal range and may represent life-threatening values.”[2] The same definition is shared by many other organisations, namely the Royal College of Pathologists (RCP) and Clinical and Laboratory Standards Institute (CLSI).[2] At national and international levels, there is evidence that suggests that policies for the implementation of their communication are heterogeneous around the world. The results of surveys conducted have emphasised that there is poor consensus regarding many aspects of CVs management, and it's concerning because the lack or delayed communication of CVs has been clearly recognised as a source of significant harm to the patients.[3]

Timely notification of CV has been endorsed as one of the leading quality indicators of the post-analytical phase by the Working Group “Laboratory Errors and Patient Safety” (WG-LEPS) of the International Federation of Clinical Chemistry and Laboratory Medicine (IFCC).[3]

There is limited evidence evaluating clinician satisfaction with laboratory performance and the impact of timely CV reporting, enabling the best use of resources for patient care.[4] Therefore, this study was designed to analyse the frequency of CVN and to assess clinician satisfaction with the notification process and its influence on patient management. Hence, we designed the present study to document the frequency of different CVs in haematology and analyse the satisfaction of clinicians towards the CVN process.

MATERIAL AND METHODS

This study was a descriptive, cross-sectional, observational, and analytical study design for the period of one year (Jan 2024 to Dec 2024). Ethics approval was obtained from the Ethics Committee of the University Sri Devaraj Urs, Medical College and Research Hospital, with the decision dated June 13th, 2025 (SDUAHER/R&D/CEC/ SDUMC-F/2/NF/-2025-26). Our aim was to analyse the CVs in the Haematology section of the Pathology Department in Sri Devraj Urs Medical College. CV is defined as any test result that is significantly deviating from the normal reference range and requires immediate clinical attention.[2] All the CVs entered in the haematology section were recorded, verified, and analysed for the past year (Jan 2024 to Dec 2024). The CVs that were selected are haemoglobin (HB) <7gm/dl and HB >20gm/dl, platelet count (PC) <40000 and >1000000, white blood cell count (WBC) <2000 and >40000. The haematology CVs used in our laboratory were based on R L Jalappa Hospital (RLJH), Central Diagnostic Laboratory Services (CDLS) institutional policy, developed in accordance with clinicians and published recommendations for the management of critical laboratory results.[5,6]

The total test performed in the haematology section included HB in 90,717, WBC in 76196, and platelets in 76,204. The CVs received were categorised according to the respective clinical departments to identify the source of the maximum number of CVs and further analysed based on patient age groups.

Critical value notification

The list of haematology parameters selected for CVN and their corresponding critical limits were established in accordance with the Standard Operating Procedures (SOPs) of the laboratory. After ruling out pre-analytical errors, samples with CVs were re-run for confirmation. Once verified, the pathology faculty re-evaluated the results, although some studies have reported that repeat testing adds little additional value.[7] and notified the treating clinician by telephone within 30 minutes of reporting. Details such as the parameter, date, time of notification, critical range, name of the faculty member informing, and recipient of the information were documented in the CV Logbook. To facilitate and expedite the CVN process, the Laboratory Information System (LIS) was utilised to flag results meeting the CV criteria.

Clinician satisfaction survey

A clinician satisfaction survey with 10 questions based on CVN was completed by the clinicians in Google Forms and analysed. The study was approved by the Institutional Ethics Committee, and informed consent from clinicians was obtained electronically through the Google Form prior to survey participation. Internal validation was performed by subject experts to evaluate the clarity, relevance, and structure of the questions. External validation was conducted through pilot testing among a small group of clinicians prior to final distribution. A total of 116 clinicians participated in the survey.

Analysis and statistical methods

The obtained parameters were evaluated using descriptive statistical analysis. The statistical analyses were performed using the IBM SPSS (Statistical Package for the Social Sciences v 22.0) and Microsoft Office Excel 2022 software.

RESULTS

The present study was a cross-sectional, observational, and analytical study conducted in Sri Devaraj URS Medical College over the period of one year (Jan 2024 to Dec 2024). The CDLS received a total of 4408 CVs in the haematology section in this period. The maximum critical tests were received from the Department of Medicine 2362 (53.5%), followed by the Department of Paediatrics (including PICU and NICU) 750 (15.1%) and OBG 428 (9.7%) [Table 1].

Table 1: List of all the listed CVs from each department.
Department Total no of CVs Percentage (%)
Medicine 2362 53.5
MICU 209 4.7
Paediatric 697 15.8
PICU 41 0.9
NICU 12 0.2
Surgery 245 5.5
OBG 428 9.7
PSM 5 0.1
EMD 96 2.1
ENT 60 1.3
Psychiatry 2 0.04
Anaesthesia 34 0.7
Nephrology 116 2.6
Ophthalmology 46 1
Orthopaedics 55 1.2
Total 4408

MICU: Medicine intensive care unit, PICU: Paediatric intensive care unit, NICU: Neonatal intensive care unit, OBG: Obstetric and Gynecology, PSM: Preventive and social medicine, EMD: Emergency medicine department, ENT: Ear nose and throat, CV: Critical value.

We also categorised the CVs received according to the age of the patients [Table 2]. Most CVs were reported in the adult age group of more than 18 years, accounting for 3,582 cases (81.2%), followed by the 6–17 years age group with 619 cases (14%), and the 0–1 year group with 148 cases (3.3%).

Table 2: The distribution of CVs according to patient age.
Age Total no of CVs Percentage
Age 0 to 1 148 3.3
Age 1 to 5 59 1.3
Age 6 10 18 619 14
Age >18 3582 81.2
Total 4408

CV: Critical values

The analytes most frequently associated with CVN were HB 2476 (2.7%), followed by Platelets 1727 (2.3%) and WBCs 166 (0.2%).

Clinician satisfaction with haematology CVN services was assessed using a 5-point Likert scale. The mean satisfaction score was 3.76, with a median score of 4, indicating an overall good level of satisfaction. Most respondents rated the service favourably, with scores clustering at 4, followed by 5, while lower satisfaction scores were reported less frequently. Qualitative feedback indicated that although the current system was considered adequate by several respondents, recurring concerns included the need for faster reporting of CVs, timely and reliable alert mechanisms, and improved interaction between clinicians and the laboratory. A small proportion of respondents also reported non-receipt of CV alerts, highlighting gaps in communication.

DISCUSSION

CV notification remains a cornerstone of laboratory practice, ensuring that life-threatening results are promptly communicated to treating clinicians. In the present study, we not only recorded the frequencies of CVs in haematology but also surveyed the clinician’s satisfaction with CVN; clinicians widely recognised its importance; however, satisfaction with the process was influenced by both the mode and timeliness of communication.

The study was conducted over one year (Jan 2024 -Dec 2024). The total number of samples examined in the haematology section was 90,717, out of which 4408 were CVs, accounting for 5.2%. The highest number of CVN was received from the Department of Medicine accounting for 2362 (53.5%), Medicine departments often manage patients with multi-system diseases, leading to frequent haematology abnormalities (e.g., anaemia, thrombocytopenia), Similar findings in Kaya et al. showed platelets and HB as the most common CVs, consistent with your observations[8] and second highest from Paediatric department 750 (15.2%) Paediatric patients often present with haematological abnormalities such as anaemia, thrombocytopenia, and leukopenia, which explains the higher frequency of CVs in this department.. The analytes most notified for CV were HB 2476 (2.7%) followed by Platelets 1727 (2.3%) and WBCs 166 (0.2%) [Table 3].

Table 3: List of critical value limit ranges of different parameters in the haematology section.
Test name Critical value Total tests Critical count % of Total tests
HB <7 90717 2476 2.7
>20 90717 15 0.02
WBC <2000 76193 166 0.2
>40000 76193 14 0.02
Platelets <40000 76204 1727 2.3
>1000000 76204 10 0.01

HB: Haemoglobin, WBC: White blood cell count

Our results were similar to those of other studies discussed here; we limited ourselves to haematology CVs only. Most clinicians recognised the importance of timely notification of CVs [Table 4].[9] Timeliness of communication was a key determinant of clinical satisfaction. All clinicians expressed satisfaction with the terminologies used in the Haematology CVN. A majority (72%) agreed that the information provided through CVN was sufficient for diagnosis and clinical decision-making. Most respondents (96.2%) affirmed that haematology CVN enhances patient safety. However, only half of the clinicians (50%) were aware of the escalation protocol currently followed in the laboratory. Nearly nine out of ten clinicians (89.3%) agreed that the existing haematology CV thresholds were appropriate.

Table 4: The comparison of frequencies of different studies to the present study.
SN Name Duration Total tests Total no of CVs %of Cvs to Total tests Sections included Analyte with the highest frequency
1 Shubha[1] 18 75,156 2199 2.9 Haematology (H) H-Platelets (165, 7.5%)
2 Present study 24 90717 4408 5.2 Haematology (H) HB 2476 (2.7%) and platelets 1727 (2.3%)
3 Dighe et al.[9] 24 90,000 19423 21.6 Haematology (H) Haematology (H) (5212, 26.8%)

CVs: Critical values, HB: Haemoglobin.

In our study, the average notification time for haematological CVs was within 30 minutes. This aligns with international recommendations such as those by the CLSI and the College of American Pathologists (CAP), both of which emphasize that CVs should be reported immediately, ideally within 15–30 minutes of validation.[10,11] However, some clinicians reported delays and that to improve TATs, particularly outside routine working hours or when contacting the responsible physician was difficult. Similar challenges have been documented in other studies, where infrastructural limitations and reliance on intermediary staff contributed to delayed communication.[5,12]

Telephone notification remains the standard method for urgent haematological CVs in our setting. While this approach ensures direct communication, it is also prone to documentation gaps. Some clinicians expressed interest in automated systems such as SMS alerts or LIS prompts. International studies have shown that such systems can improve efficiency and reduce turnaround times.[5,13] However, their adoption in resource-limited environments may be constrained by infrastructure, medico-legal considerations, and the need for reliable audit trails. Documentation and accountability emerged as important themes in our findings. Accurate recording of who received the notification, the time of reporting, and subsequent action is essential both for clinical quality improvement and medico-legal protection. Accreditation standards such as ISO 15189 emphasise periodic audits of the CVN process to ensure compliance and identify gaps.[13]

Our study was restricted to haematological CV and therefore does not reflect practices related to biochemical or other laboratory parameters. Being a single-centre study, the findings may not be generalizable to all healthcare settings. Additionally, the survey relied on clinician self-reporting, which introduces potential recall and response bias. The impact on patient’s outcomes was also not assessed.

Despite these limitations, the study provides valuable insight into the strengths and challenges of haematological CVN in our institution. The findings underscore the importance of clinician sensitisation, timely communication protocols, and reliable documentation practices. Periodic review of the CV list, reinforcement of reporting policies, and exploration of digital tools may further enhance the process.

In conclusion, effective notification of haematological CV such as Haemoglobin, platelet count, and WBC count is vital for patient safety. Our findings highlight the importance of strengthening awareness, minimising delays, and ensuring robust documentation to optimise clinician response and improve outcomes.

CONCLUSION

Efficient and timely communication of critical test results is a fundamental responsibility of clinical laboratories. The increasing integration of information technology (IT) in medical laboratories offers valuable opportunities to enhance rapid communication with clinicians, thereby improving patient care and clinical decision-making. Most CVs were reported from the Department of Medicine, with adults forming the largest affected age group.

The survey demonstrates that clinicians are largely satisfied with the existing Haematology CVN system. However, the feedback reveals important opportunities for improvement, particularly with respect to timeliness, reliability of alerts, and communication efficiency. Addressing these areas is crucial for strengthening patient safety and supporting prompt clinical decision-making.

Authors’ contributions:

GAB: Contributed to study design, data collection, analysis, drafting, and approval of the final manuscript, handled submission, journal communication, revisions, and final approval coordination; TNS: Concept building, guidance, data analysis and final approval; RA: Concept building, guidance, validation and clinician satisfaction survey.

Ethical approval:

The research/study was approved by the Institutional Review Board at Sri Devaraj Urs Medical College, Number SDUAHER/R&D/CEC/SDUMC- F/ 21/ NF/-2025-26, dated 13th June 2025.

Declaration of patient consent:

The authors certify that they have obtained all appropriate participants' consent.

Conflicts of interest:

There are no conflicts of interest.

Use of artificial intelligence (AI)-assisted technology for manuscript preparation:

The authors confirm that there was no use of artificial intelligence (AI)-assisted technology for assisting in the writing or editing of the manuscript, and no images were manipulated using AI.

Financial support and sponsorship: Nil.

References

  1. . A study of critical value analysis at hematology and biochemistry sections of laboratory in a multispecialty hospital. Panacea J Med Sci. 2022;12:430-5.
    [CrossRef] [Google Scholar]
  2. . National Patient Safety Goals. . Available from: https://www.jointcommission.org/hap_2016_npsgs [Last accessed 2016 Sep 22]
    [Google Scholar]
  3. , . Critical laboratory values communication: Summary recommendations from available guidelines. Ann Transl Med. 2016;4:400.
    [CrossRef] [PubMed] [Google Scholar]
  4. , , , . Physician satisfaction with clinical laboratory services: A College of American Pathologists Q-Probes study of 81 institutions. Arch Pathol Lab Med. 2016;140:1098-103.
    [CrossRef] [PubMed] [Google Scholar]
  5. . Management of critical- and significant-risk results (GP47) Available from: https://clsi.org/standards/products/critical-and-significant-risk-results/ [Last accessed 2026 Aug 2]
    [Google Scholar]
  6. , . Harmonization of critical result management in laboratory medicine. Clin Chem Lab Med. 2014;52:951-9.
    [Google Scholar]
  7. , , , , , , et al. Necessity of routine repeat testing of critical values in various working shifts. Iran J Pathol. 2020;15:161-6.
    [CrossRef] [PubMed] [Google Scholar]
  8. , , , , . Clinicians' perspectives on critical outcomes. Turk J Biochem. 2025;50:123-30.
    [Google Scholar]
  9. , , , . Analysis of laboratory critical value reporting at a large academic medical center. Am J Clin Pathol. 2006;125:758-64.
    [CrossRef] [PubMed] [Google Scholar]
  10. . ISO 15189:2012. Medical laboratories—Requirements for quality and competence. 2012 Available from: https://www.iso.org/standard/56128.html [Last accessed 2026 Aug 2]
    [Google Scholar]
  11. . Q-Tracks Program: Critical Values Reporting. . Northfield (IL): College of American Pathologists; Available from: https://q-tracks.cap.org/Pages/default.aspx [Last accessed 2026 Aug 2]
    [Google Scholar]
  12. , , , . Identification and notification of critical values at a tertiary care hospital. Indian J Clin Biochem. 2017;32:239-43.
    [Google Scholar]
  13. , , , . Laboratory critical values: Automated notification supports effective clinical decision making. Clin Biochem. 2009;42:904-8.
    [Google Scholar]
Show Sections